For sterilizer, washer-disinfector and thermal cycler validation Anville offer a range of thermocouples for use with the Series 825 TVI. Constructed using the best quality material for accurate and repeatable measurements the thermocouples are manufactured using class type T material in ptfe sheathing.

Sterilizer and washer-disinfector validation thermocouple

Anville 10B_T_CLASS1_5000_CAP_5A

  • Part number 10B-T-CLASS1-5000-CAP-5A.
  • Temperature range -250°C to +250°C.
  • Accuracy ±0.5°C.
  • Material Class 1 type T ptfe sheathed.
  • Length 5m other lengths to order.
  • Connection Miniature thermocouple plug.

Thermal cycler validation thermocouple for 0.2ml wells

Anville 15A_T0.2_PTFE_1000_5A

  • Part number 15A-T0.2-PTFE-1000-5A
  • Temperature range -50°C to +150°C.
  • Accuracy ±0.5°C.
  • Material Class 1 type T ptfe sheathed.
  • Length 1m, other lengths to special order.
  • Connection Miniature thermocouple plug.

Thermal cycler validation thermocouple for 0.5ml wells

Anville 15A_T0.5_PTFE_1000_5A

  • Part number 15A-T0.5-PTFE-1000-5A
  • Temperature range -50°C to +150°C.
  • Accuracy ±0.5°C.
  • Material Class 1 type T ptfe sheathed.
  • Length 1m, other lengths to special order.
  • Connection Miniature thermocouple plug.

Pressure transducer

For sterilzer and washer-disinfector validation a standard pressure transducer is not adequate as the process temperature is frequently in excess of 80°C. The Ashcroft KXDHT tranducer is designed for continuous operation at process temperature up to 150°C and is much better suited for the purpose. It can be used directly connected to the machine with no cooling loop. Supplied with a fixed cable terminated with a plug suitable for the Series 825 TVI. Other plugs can also be supplied.

Ashcroft KXDHT pressure transducer

  • Part number KXDHT.
  • Pressure range -1 bar to 4 bar gauge.
  • Accuracy ±0.25%.
  • Span thermal drift ±0.03%/°C.
  • Repeatability 0.03% full scale
  • Median temperature range -30°C to 150°C.
  • Operating temperature range -30°C to 85°C.
  • Over pressure limit 10 bar.
  • Signal output 4-20mA.
  • Power supply 24VDC from Anville data logger.
  • Process connection G 1/4" male.
  • Process connection material Stainless steel 3 16Ti.
  • Connection 3m captive cable terminated with a plug to suit.

 

Ashcroft pressure transducer and pressure calibrator
Ashcroft pressure transducer and pressure calibrator

Popular Pages

Thermal Validation

Sterilizer Validation

Washer Disinfector Validation

Thermal Cycler Validation

Industrial Automation

CSSD Monitoring

Downtime Monitoring

Popular Documents

EaziVal Quick start guide

EaziVal 2 User guide

EaziVal SE User guide

 

 

Anville Instruments Ltd

Bramble Orchard
46a Folly Lane North
Farnham
Surrey GU9 0HX
United Kingdom

Email Us
Tel: +44 (0)1252 351030

web development: 1 choice internet ltd.